Table 2 Reconstruction time of different tomographic volumes

From: Towards on-the-fly data post-processing for real-time tomographic imaging at TOMCAT

Dataset

TIFF (s)

HDF5 (s)

Sinogram

Reconstruction

Total

Sinogram

Reconstruction

Total

Ultrafast

3.8

1.0

4.8

2.7

1.0

3.7

Fast

–

–

–

6.6

6.0

12.6

Standard

17.7

14.7

32.4

10.2

15.2

25.4

Highres

26.5

50.2

76.7

–

–

–